NOTE: New option modules may not be supported by CPUs purchased prior to the modules release.
Be sure to check for the latest firmware for your PLC. You can refer to the module specification page on our main Web site for this information, or find it in our free catalog.
Here is the direct link to the Firmware Upgrade section of our Web site where you can find the firmware revision histories, the latest files and tools required to download the firmware into your CPU.
Analog, DeviceNET, Ethernet, data communications, high-speed counting/ pulse output, thermocouple input, RTD temperature input and Profibus option modules for the DirectLOGIC 06 (DL06) programmable logic controller are also available.
The discrete I/O option cards allow the DL06 PLC to expand with the needs of your industrial process control applications for just a few dollars more. Combine our 16-point discrete output modules with ZIPLink relay modules to control high current loads, such as air solenoids or hydraulic valves.
Available discrete modules include:
|
F0-08NA-1 [$Call] - 8 point 110 VAC input module. [data sheet] (pdf)
1 common (2 common terminals), removable terminal block |
|
D0-10ND3 [$Call] - 10 point 12-24 VDC current sinking/sourcing input module. [data sheet] (pdf)
2 isolated commons (5 points per common), removable terminal |
|
D0-10ND3F [$Call] - 10-point 12-24 VDC current sinking/ sourcing, input module. [data sheet] (pdf)
Fast response, 2 isolated commons (5 points per common), removable terminal. |
|
D0-16ND3 [$Call] - 16 point 20-28 VDC current sinking/sourcing input module. [data sheet] (pdf)
4 isolated commons(4 points per common). One pre-wired ZIPLink cable ( 0.5 meter) and terminal block connector module required for this I/O module. |
|
D0-10TD1 [$Call] - 10 point 12-24 VDC current sinking output module. [data sheet] (pdf)
2 commons non-isolated (5 points per common), 0.3 A/point, 1.5 A/common, removable terminal, no fuse |
|
D0-10TD2 [$Call] - 10 point 12-24 VDC current sourcing output module.[data sheet] (pdf)
2 commons non-isolated (5 points per common), 0.3 A/point, 1.5 A/common, removable terminal, no fuse
|
|
D0-16TD1 [$Call] - 16 point 12-24 VDC current sinking output module. [data sheet] (pdf)
2 commons non-isolated (5 points per common), 0.3 A/point, 1.5 A/common, removable terminal, no fuse. One pre-wired ZIPLink cable ( 0.5 meter) and terminal block connector module required for this I/O module. |
|
D0-16TD2 [$Call] - 16 point 12-24 VDC current sourcing output module. [data sheet] (pdf)
2 commons non-isolated (8 points per common), 0.1 A/point, .8 A/common, removable terminal, no fuse. One pre-wired ZIPLink cable ( 0.5 meter) and terminal block connector module required for this I/O module. See Compatibility Matrix in the ZIPLink technical section to choose cable and connector module. |
|
F0-04TRS [$Call] - 4 point 5-30 VDC or 5-125 VAC isolated relay output module. [data sheet] (pdf)
2 Form A (SPST) relays, 2 Form C (SPDT) relays, 4 isolated commons, 3 A/point, replaceable fuse, removable terminal block. |
|
D0-08TR [$Call] - 8 point 6-27 VDC or 6-240 VAC relay output module. [data sheet] (pdf)
8 Form A (SPST) relays, 2 isolated commons, 1 A/point, 4 A/common, removable terminal |
|
D0-08CDD1 [$Call] - 4 point 12-24 VDC current sinking/sourcing input. [data sheet] (pdf)
1 common, 4 point 12-24 VDC sinking output, 0.3 A/point, 1.2 A/module, removable terminal, no fuse |
|
D0-07CDR [$Call] - 4 point 12-24 VDC current sinking/sourcing input. [data sheet] (pdf)
1 common, 3 point relay output, 3 Form A (SPST) relays 1 A/point, 3 A/module, 1 common, no fuse
|
|
F0-08SIM [$Call] - 8 point input simulator module [data sheet] (pdf)
5 VDC base power required (1 mA). |
|